Fensor Humidity Generator

0 out of 5

FOR ALL TYPES OF HYGROMETERS
The HG-101 allows simple and rapid realization of relative humidity calibration of sensors, probes, loggers
and recorders from any manufacturer.
Interchangeable probe ports are available to fit most types of instrument and the measuring chamber is
replaceable allowing Metrologists validate most types of measurement equipment.
The standard probe test cell has 7 ports for probes up to 30mm in diameter.
Test cells with up to 7 probe ports and customized solutions to suit different instrument types such as loggers with
integrated sensors are available.

We use the HG-101 for all on-site humidity calibration testing. With its portability, speed and traceability its the right tool for the job.

Contact us at Calitec or head directly to Fensor for more info.

Category: Calibration

Description

EASY TO OPERATE,
STABLE MEASUREMENT, FAST RESPONSE TIME
Once the instruments under test are inserted in to the test cell, the operator just needs to set the required humidity
value using the panel mounted switches or by software through the USB interface.
Free apps for Android and Windows. The HG-101 is very fast to reach a target RH value in typically 30 seconds thanks to the innovative RDSa mixing system.
Stability is better than ±0.2 over the range 10 to 90 %rh. Over the full 5 to 95 %rh range, extended stabilisation time is necessary to reach the best performance.
The HG-101 humidity generator does not use a liquid water reservoir, so it can be used in different positions depending on the requirements of the calibration.
Similarly, no particular care (emptying, cleaning, drying) is required between uses or during transportation.

LOW RH UNCERTAINTY UP 50°C
Humidity calibration can be performed over a temperature range of 5 to 50 °C by placing the HG101 in a climatic chamber. Set points can be changed
remotely through the HG101s USB interface and control software installed on a PC, tablet or smartphone.
The HG-101 is designed to be used within a thermostatically controlled chamber or enclosure, without compromising the homogeneity of
the temperature inside the HG101 measuring chamber. To do this, the materials used for the calibrator were selected to promote thermal diffusivity
and low hygroscopicity.
To reduce uncertainty and external influences, the structure is configured to minimize cold spots, promote heat distribution and ensure consistency in
temperature. As relative humidity is so temperature dependent, this means the temperature related contributions to RH calibration uncertainty are minimised.

For more info click on the link below.

          Fensor